Description:
Download : Datasheet of USS-SC100A-TM-O
Specification:
Model | USS-SC100A-TM-O |
Display content | When the temperature is measured, the temperature display area shows the actual temperature the number of alarm. When the running indicator is green, it is ready to operate. When the alarm light turns red, a temperature exceeding the threshold is detected or metal objects are detected. The signal indicator indicates the presence or absence of interference in zones 1-18 from bottom to top. The signal light can show the detected objects’ metal content, the more metal in the item, the brighter the alarm light. |
Temperature detection range | 35℃~42℃ |
Temperature error | ±0.5℃ |
Accuracy | 0.02℃ |
Metal detection zone mode | 18 metal detection areas |
Metal detection accuracy | With the function of adjusting sensitivity, each location can set the sensitivity of 200 levels (0~200), the smallest metal object size that can be detected is 30mm*30mm*2mm. |
Password protection | Only authorized personnel can operate. |
Power supply | AC220V/50HZ |
Power consumption | <20W |
Operating temperature | 10℃~45℃ |
Operating humidity | <80% RH |
Weight | 45KG |
Overall dimension | 2270mm*830mm*500mm |
Channel dimension | 2000mm*700mm*500mm |
Notes | The installation environment should be rainproof, moisture-proof and dry, and the environment temperature balance should be kept as far as possible. High temperature objects and large metal item should be kept away from the security gate. Chemical agents such as 84 disinfectant and 75% ethanol disinfectant should be avoided from corroding the outer membrane of the temperature control probe. |